Non – Chlorine based wash after each milking

Hydra-MIL followed by Cluster Clear

  1. Wash the outside of the clusters, attach jetters and remove milk filter sock
  2. Pre-rinse plant thoroughly with 15L of cold water per unit
  3. Cold Wash: Add 500g of Hydra-MIL powder to 100L of cold water
    Hot Wash: Add 300g of Hydra-MIL powder to 100L of hot water (65 – 75 ⁰C)
  4. Circulate the solution throughout the milk line for seven to 10 minutes (the solution may be retained for a second daily wash, but must be discarded
    after second wash)
  5. Rinse the plant immediately after the main wash cycle with 15L of cold water per unit
  6. Ensure the system is drained sufficiently before the next milking

NEVER LEAVE SOLUTION OR WATER IN THE LINE BETWEEN MILKINGS

When using Cluster Clear following main wash

  1. Following step 4, carry out an intermediate rinse of the milk plant at a rate of 9L of cold water per unit
  2. Add 100ml of Cluster Clear to 50L of cold water
  3. Circulate for seven to 10 minutes
  4. Discard the solution
  5. Carry out a final rinse, at a rate of 15L of cold water per unit
  6. Ensure the system is drained sufficiently before the next milking

It is recommended to use Cluster Clear every second day for optimum sterilisation.